top of page

110 results found with an empty search

  • Mentions légales | LIM SAS

    In accordance with article 6 of the n°2004-575 law of the 21 june 2004 about trust in the digital economy, managers of the present website are : Site editor LIM SAS Amount of capital 446 834,37 Euros Legal form Simplified joint-stock company (SAS) SIRET number 38782045900015 Editorial manager LIM SAS Address 86 rue Jean Bertin 69100 Villeurbanne (France) Phone number +33 4 72 14 68 30 Fax +33 4 72 37 72 76 Email info@lim.eu Websites LIM SAS website Hosting company WIX Hosting company address 500 Terry A François Blvd San Francisco, CA 94158 Hosting company website Site web WIX Terms of use For a better use and a better design experience, we recommend you to install modern browsers such as Google Chrome, Firefox, Safari and many others. LIM SAS has made his best to offer you reliable informations and updates on his website. Despite all that, mistakes and omissions can happen. The web user should verify the accuracy of the information and report any useful modification. LIM SAS can not be accuse for the use of those informations or any direct or indirect prejudice. Hyperlinks LIM SAS has no way to control website connected to his website and can not guarantee the fiability of those websites and their external links. LIM SAS can not be responsible of any damage caused by those websites. The web user is responsible for those risks.

  • FOR EXPLORATION | LIM GROUP

    Our solutions for exploration drilling. Recording of drilling parameters and logging probe, televiewer for borehole imaging and core scanner. EXPLORATION PocketLIM 6G Bohrungen, Wasserbohrungen, Geothermische Bohrungen. Televiewer Optischer und akustischer Betrachter. Schallsonden, Nuklearsonden, elektrische Sonden, hydraulische Sonden und Bohrgeometriesonden. ScanLIM et ScanLIM-LIBS Bohrkernscanner mit Metallgehaltserkennung. ➭ CONTACT US

  • Drilling fleet management / automatic transmission of drilling data | LIM SAS

    Drill@Lim provides real-time information on the operation and geolocation of the drilling machine. Allows you to monitor your teams in the field in real time. Lim@mail is a service that synchronises, downloads and automatically pre-processes your drillings or any in situ tests. Drill@LIM Real-time monitoring of drilling machine operation with geolocation Drill@LIM is a cloud solution that provides real-time information on the operation and geolocation of the drilling machine. A single piece of equipment installed on the drilling machine (regardless of its brand and model), the PocketLIM manages all the sensors for the drilling machine, the machine and the engine. Drill@LIM helps to manage, control and monitor in real time a fleet of drill rigs by getting information on the status of machines (engine parameters, machine parameters, alerts, ..). Recorded LIM data download and pre-processing LIM@mail performs real-time synchronization, transfer and automatic pre-processing of BOR data files generated by the PocketLIM, MiniLIM and NanoLIM . Contact us to get a quote or request more information. LIM@Mail Back PDF VERSION (Drill@LIM) Drill@LIM CASE STUDY PDF VERSION (LIM@Mail) GEO-LOG 4 LIMsoft

  • 4 Arms Caliper probe | LIM LOGGING

    4AC 4AC60 : Four-arm caliper probe The 4AC60 borehole geometry probe incorporates two pairs of caliper arms giving independent, perpendicular X-Y diameter measurements, while a magnetometer/accelerometer orientation system provides the borehole azimuth, inclination and X-Y arm directions. In a non-circular borehole, because of differing spring tensions in the two pairs of arms, the tool will rotate in the borehole until the X-Y directions coincide with the maximum and minimum diameter axes. Where a borehole becomes ovalised or develops breakout-type features, it can provide information on stress magnitudes and directions within the geological formations. As an option, the probe can be supplied with a natural gamma detector to provide additional lithological information or for horizon correlation purposes. Contact us to get a quote or request more information. PDF VERSION 4AC60 SPECIFICATIONS Technical specifications ✓ Diameter : 60 mm ✓ Length : 3100 mm ✓ Weight : 18 kg ✓ Max. temperature. : 70°C ✓ max. Pressure: 200 bar ✓ Power: 70 to 100 Vdc Data / sensor parameters ✓ Diameter range: 60 to 450 mm ✓ Diameter resolution: 0.1 mm ✓ Orientation sensor: triple magnetometers : accelerometers ✓ Measurement range: Full 360°inclin./ azimuth ✓ Orientation precision : +/- 0,1° inclination, +/-0,5° azimuth Accessories & options ✓ Natural Gamma detector: ø25x50 mm NaI(Tl) crystal ✓ Non magnetic centralisers ✓ Calibration Jig Borehole conditions ✓ Dry or fluid-filled borehole ✓ Open hole or PVC casing if azimuth required ✓ Steel casing if azimuth not required All downhole probes

  • Borehole logging Probes | LIM LOGGING

    Complete set of probes for Geotechnical investigation, hydrogeologie and borehole geometry. Provide real-time data for downhole logging, application for well logging in some cases. Downhole Probes LIM probes, renowned for their build quality and simple, intuitive Logger/probe interface, can be used for a wide range of recording applications. The name of our probes contains a number which indicates the diameter of each probe. Borehole imaging - televiewers: OPTV 38 & 52 : Optical Borehole Televiewer BHTV 42 : Acoustic Televiewer BHTV 42 : "Casing Thickness option Borehole geometry: BDV42 : Borehole Deviation 3AC38 : Three-arm caliper probe 4AC60 : Four-arm caliper probe GYR38 Gyroscopic Natural Gamma Ray Probe GR38 & GR25 : Natural Gamma Radioactivity GRS42 & 60 : Spectral Gamma GRT38 : Natural Gamma + Temperature GRT38 : CCL + Natural Gamma + Temperature Full Wave sonic probes: FWS60 : Fullwave Sonic (3 & 4 receivers) Electric probes: ELG46 : Electric Logging EM25 : Slim Single Induction DIL38 : Dual Induction GUIP38 : Focused Electric IP38 : Induced Polarisation MAG38 : Magnetic Suceptibility Nuclear probes: TRS38G : Trisonde (Density) UEP42 : Uranium Exploration PDGC50 : Photo-Electric Density Contact Us Hydraulic probes: FTC60 : Temperature/Conductivity/Flowmeter WQP48 : Water Quality TC25: Temperature & Conductivity Accessories: PDS : Probe Deployment System Fishing Tool Tripod Back

  • Water quality probe | LIM LOGGING

    WQP38. WQP48: Water Quality The WQP48 probe provides precise readings of the principal fluid parameters of interest in a hydrogeological or environmental context. A calibration interface cable, standard solutions and maintenance kit are provided with the probe to ensure performance remains within specifications. The probe calibration routines can be accessed without removing the pressure housing. Contact us to get a quote or request more information. PDF VERSION CASE STUDY WQP48 SPECIFICATIONS Technical Specifications ✓ Diameter (sensor cage / tool body): 48 mm / 42 mm ✓ Length : 1 670 mm ✓ Weight : 7.5 kg ✓ Max. operating temperature : 70°C ✓ Max. operating pressure : 150 bar Sensors Parameters ✓ Pressure range : 1500 dbar ✓ Temperature range : -1 to 50°C ✓ Conductivity range : 0 to 70 mS/cm ✓ Dissolved 02 range : 0 to 50 ppm ✓ pH range : 0 to 14 ✓ Redox potential range : ±1000 mV ✓ Pressure resolution : 0.03 dbar ✓ Temperature resolution : 0.001°C ✓ Conductivity resolution : 0.001 mS/cm ✓ Dissolved 02 resolution : 0.01 ppm ✓ pH resolution : 0.001 ✓ Redox potential resolution : 0.1 mV Options And Accessories ✓ Additional sensors available : Nitrate, Ammonia, Chloride Sulphide, Iodide, Copper ✓ Bowspring centralisers Borehole Conditions ✓ Fluid-filled borehole ✓ Open or cased borehole WQP48 GALLERY To play, press and hold the enter key. To stop, release the enter key. All downhole probes

  • DTN38 probe | LIM LOGGING

    DTN38, Dual Neutron thermal probe, neutron neutron, dual neutron. DTN38: Dual Thermal Neutron The standard DTN38 probe provides long-(LSN) and short-spaced(SSN) 4π thermal neutron measurements. Since the probe reacts strongly to hydrogen content, the principal application of this method is for formation water content (porosity) measurement. As an option (highly recommended), the probe can be supplied with a natural g amma detector to permit the influence of clay content on the results to be evaluated. Useful when the probe is deployed for through-tubing oil/water/air contact measurements, a casing collar locator (CCL) detector is also available as a factory-fitted option for this probe. Contact us to get a quote or request more information. PDF VERSION DTN38 SPECIFICATIONS Technical Specifications ✓ Diameter : 38 mm ✓ Length : 2330 mm ✓ Weight : 12 Kg ✓ Max. Temp : 70°C ✓ Max. Pressure : 200 bar Sensors Parameters ✓ Thermal neutron detectors : 25x200mm He³tube(4 bar) ✓ Source – detector spacings : 24 cm (SSN), 48 cm (LSN) ✓ Source type : Am/Be (mean energy 4MeV) ✓ Recommended source activity : 37 GBq (1 Ci) Options And Accessories ✓ Source holder ✓ Source transport container ✓ Natural gamma detector : ø25 x 50mm NaI(Tl) crystal ✓ CCL detector Borehole Conditions ✓ Fluid-filled borehole recommended ✓ Open or cased borehole All downhole probes

  • Spectral Gamma Probe | LIM LOGGING

    GRS, Gamma Ray Spectral. Able to resolve discrete gamma ray energy levels. GRS42 & 60: Spectral Gamma The detector assembly comprises of a 25 x 50 mm ( GRS42 ) or 50 x 150 mm ( GRS60 ) cylindrical NaI crystal coupled to a thermally stabilised photomultiplier tube. According to type the probe is capable of resolving 250 or 500 discrete gamma ray energy levels over the range 60 to 3 060 keV. Count rates from all of which are transmitted to the surface during logging. Subsequently, discrete windows centred on the characteristic K, U and Th peak levels are used to derive the concentration of these radio-elements. Contact us to get a quote or request more information. PDF VERSION CASE STUDY GRS42 SPECIFICATIONS Technical Specifications ✓ Diameter GRS 42 : 42 mm ✓ GRS 60 : 60 mm ✓ Length : 1120 mm ✓ Weight : 7 Kg ✓ T° Max. : 70°C ✓ Pressure Max : 200 bar Sensors Parameters ✓ Detector GRS 42 : 25 x 50 mm ✓ Detector GRS 60 : 50 x 150 mm ✓ Spectral energy range : 60 to 3060 keV ✓ Spectral resolution : GRS 42 : 250 channels, 12 keV per channel ✓ Spectral resolution : GRS 60 : 500 channels, 6 keV per channel Borehole Conditions ✓ Dry or fluidfilled ✓ Open-hole or through steel or PVC casing 75mm minimum GRS42 GALLERY To play, press and hold the enter key. To stop, release the enter key. All downhole probes

  • Borehole Optical Televiewers | LIM LOGGING

    A precision wide angle lens permit the OPTV38 and OPTV52 probes to capture a high-definition video image of the borehole wall in a variety of horizontal and vertical resolutions. OPTV 38 & 52 : Optical Televiewer A precision wide angle lens and a CMOS camera assembly permit the OPTV38 and OPTV52 probes to capture a high-definition video image of the borehole wall in a variety of horizontal and vertical resolutions. The resulting image data is digitised in the probe and combined with orientation sensor parameters for transmission to the surface. The orientated image log provides a wealth of information relevant to a wide variety of applications. These include fracture detection and analysis, bedding or foliation dip and direction, lithological characterisation and core sample orientation. Contact us to get a quote or request more information. PDF VERSION BOREHOLE IMAGING CASE STUDY OPTV LOG EXAMPLE 1/1 OPTV38 & 52 PROBE FEATURES Highlights ✓ Wide angle 360° lens ✓ Horizontal resolution up to 1440 pixels ✓ Throughput up to 60 frames per second ✓ High pressure resistant ✓ Log speed until 3.6 m / min ✓ Vertical resolution unlimited ✓ Depth up to 2000m Technical Specifications ✓ Diam : 38mm/52mm ✓ Weight : 7Kg ✓ Housing : titanium and brass non-magnetic ✓ Length : 1630 mm ✓ Temp / pressure max : 60°C / 100 bar Sensors Parameters ✓ Camera sensor : 1 280 x 1 024 pixels CMOS ✓ Horizontal definition : 360/540/720/900/1080/1260/1440 pixels ✓ Orientation : triple magnetometers / accelerometers ✓ Picture format : 24 bit RGB ✓ Vertical definition : unlimited (defined to logging speed) ✓ Orientation accuracy : ± 0.5° dipping ; ± 1° azimuth Options And Accessories ✓ Gamma ray sensor: ø25 x 50 mm NaI(Tl) crystal ✓ Centralisers non-magnetic ✓ Image reference calibrator ✓ High pressure version : ø62 mm / 200 bar (± 2 000 m) ✓ Supplementary sinker weight Borehole Conditions ✓ Hole dry or filled with clear water ✓ The probe must be centered ✓ Recommended diameter range for OPTV38 : 60 to 300 mm ✓ Recommended diameter range for OPTV52 : 75 to 600 mm All downhole probes

  • PDGC50 probe | LIM LOGGING

    PDGC50, Photo-Electric density probe. PDGC50: Photo-Electric Density PDGC50 provides a classic triple-spacing sidewall focussed formation density measurement, with the additional advantage of a incorporating a photo-electric effect energy detection window on the medium-spacing detector. The photoelectric effect (Pe) measurement is a reliable indication of the apparent formation atomic number, meaning that formation lithology and an accurate porosity can often be deduced directly from the results given by the probe. When the Pe log results are combined with those obtained from other probes (eg. spectral gamma) a considerable number of specific « heavy » minerals can be identified. A gamma ray source (Cs137, typically 3.7 GBq), is fixed to the lower extremity of the probe during logging. The source capsule itself is supplied separately by a specialist partner. The mechanical side-walling arm provides a caliper measurement, useful for diameter correction purposes and mud-cake evaluation, and a natural gamma log is a lso obtained by means of a scintillation detector located in the uppermost part of the probe body. Contact us to get a quote or request more information. PDF VERSION PDGC50 SPECIFICATIONS Technical Specifications ✓ Diameter : 50 mm ✓ Length : 2500 mm ✓ Weight : 20 Kg ✓ Max. Temp : 70°C ✓ Max. Pressure : 200 bar Sensors Parameters ✓ Long-spacing density : 25 x 50 mm NaI(Tl) crystal ✓ Medium-spacing density + Pe : 10 x 50 mm NaI(Tl) crystal ✓ Bed resolution density : 10 x 25 mm NaI(Tl) crystal ✓ Caliper range : 50 to 450 mm ✓ Natural gamma detector : 25 x 50 mm NaI(Tl) crystal Options And Accessories ✓ Workshop calibration blocks : plexiglass, aluminium, iron ✓ Caliper calibration jig Borehole Conditions ✓ Open uncased borehole ✓ Dry or fluid-filled (preferred) borehole All downhole probes

  • GYROPROBE GYR37 | LIM LOGGING

    The GYR38 is a gyroscopic bore deviation sensor specifically designed for demanding drilling and mining environments. GYR38 Gyroscopic Probe – Borehole Deviation Measurement GYR38 Gyroscopic Probe – Borehole Deviation Measurement A gyroscopic probe (or gyroscope) is a sensor that measures the rotational velocity of an object around an axis. It allows determining the orientation and angular movements of an object in space. These sensors are used in many applications, ranging from smartphones to ship stabilization systems. The GYR38 is a gyroscopic borehole deviation probe specifically designed for the demanding environments of drilling and mining operations. This north-seeking device (for probe inclination values between 3° and 177° from vertical) accurately provides continuous trajectory data in non-vertical boreholes. A north search time of only 2 minutes and a 60-minute measurement time between corrections help maximize operational efficiency. The GYR38 probe operates in wired mode via our proven eMindLogger acquisition unit. The borehole azimuth and inclination from the IMU are displayed in real time at the surface in our standard 6CH logging software. Additionally, optional parameters such as natural gamma and/or a CCL (Casing Collar Locator) detector can be added to the base probe. Contact us today to request a quote or for more information. PDF VERSION All downhole probes

  • ScanLIM | LIM SAS

    ScanLIM, Core scanner, Core scanner LIBS. ScanLIM-2 The ScanLIM-2 allows the user to create a virtual "corestore" of high quality, true colour and correctly scaled digital images. With a few mouse clicks, it is possible to retrieve and display selected zones or reconstruct an entire borehole. Borehole information is included in the data files in order to ensure systematic archiving. The system is transported in kit form and can be assembled and operational on site within 20 minutes. The core scaning itself is a oneman operation. Contact us to get a quote or request more information. PDF VERSION Back ScanLIM SPECIFICATIONS ✓ Dimensions: 230 cm x 120 cm x 60 cm / 90.5" x 47.2" x 23.6"; ✓ Operating temperature : +5°C à +45°C / 41°F to 113°C; ✓ Storage temperature : -25°C à +60°C / -13°F to 140°F; ✓ Humidity : 20% to 80% non-condensing; ✓ Camera : Matrix caméra, 4096 pixels/line, 100 millions of pixels for a one meter (3.3 ft) image; ✓ Image format : jpeg; ✓ HMI: Dedicated laptop provided by LIM with specific OS; ✓ Max length acquisition : 120 cm / 47.2"; ✓ Max width acquisition : 15 cm / 5.9"; ✓ Lighting : Natural/UV short 280nm, UV long 385nm; ✓ Maximum acquisition speed: 2 m/min / 6.5ft/min; ✓ Power Supply : 110 to 220 VAC; ✓ Positioning aid: laser & optical; ✓ Auto image calibration. Technical Specifications ScanLIM: PHOTO GALLERY To play, press and hold the enter key. To stop, release the enter key.

bottom of page