  • EM25 Single Induction Probe | LIM LOGGING

    EM25, Single induction probe. EM25: Single Induction (small diameter) The Slim Single Focused Induction EM25 sonde uses a three-coil focused electromagnetic array to provide a conductivity log . An oscillating high frequency magnetic field from a transmitter coil inside the probe induces an alternating electrical current within the surrounding conductive formation. This current, in turn, induces a voltage within receiver coils in the probe proportional to the formation conductivity. The transmitter-receiver spacings determine the depth of investigation of the measurements. Additional focusing coils minimize the contribution of the borehole signal. The sonde coil spacings are optimized to achieve high vertical resolution and a deep radius of investigation, with minimal borehole influence when logging in conductive-fluid-filled boreholes. The Slim Single Focused Induction EM25 sonde main features are : Formation conductivity measurement in dry or fluid-filled borehole or even in PVC casing Phase detector discriminates between magnetic susceptibility and conductivity signals Natural gamma measurement available for correlation Contact us to get a quote or request more information. EM25: PROBE FEATURES Technical Specifications ✓ Length : 1950mm ✓ Diameter : 25mm(1”) ✓ Weight : 2,5kg ✓ Max. Temp / Pressure : 70°C / 200 bar Sensors Parameters ✓ Operating Frequency : 39.062 kHz ✓ Number of coils : 4 ✓ Effective Tx-Rx Spacing : 50cm (20”) ✓ Measuring Range : 0 to 3000mS/m ✓ Resolution : 0.2mS/m ✓ Drift over T°range : <5mS/m Options And Accessories ✓ Gamma ray sensor: NaI(TI) scintillation crystal; 13mm x 50mm ✓ Field Calibrator EM25 GALLERY To play, press and hold the enter key. To stop, release the enter key. All downhole probes

  • CASE STUDIES - LOGGING | LIM GROUP

    You will find all of our Case Studies on the topics Geophysical Borehole Logging, Borehole Imagery, Hydrogeology here. Case studies : Logging Here you will find all the case studies carried out by our teams on our logging equipment (LOGGING). Borehole imaging (optical and acoustic), mining exploration Download (PDF format) Optical imaging and geophysical logging as part of a dam condition assessment (EN) Download (PDF format) Hydrogeology, water source exploration Download (PDF format) Spectral Gamma Logging Download (PDF format) Water Quality Download (PDF format) Magnetic susceptibility Download (PDF format) Induced polarisation Download (PDF format) Full Wave Sonic Download (PDF format) Temperature/Conductivity/Flow Download (PDF format) Focused resistivity Download (PDF format) Dual Induction Download (PDF format) ➭ CONTACT US

  • Dual Induction Probe | LIM LOGGING

    The DIL38 induction conductivity probe generates an electromagnetic field and provide two simultaneous conductivity logs. DIL38: Double Induction The DIL38 induction conductivity probe generates an electromagnetic field in the vicinity of the borehole and measures the response of the formations to this applied field. On both long (ILD) and medium spacing (ILM) receivers in-phase and quadrature measurements are taken and digitised by the probe electronics for transmission to the surface equipment. In this way both formation conductivity and magnetic susceptibility data can obtained, even in dry or PVC equipped boreholes. The relatively low operating frequency and the design of the coil array combine to minimise borehole effects and maximise both depth of investigation and vertical resolution. Contact us to get a quote or request more information. dil38-illustration dil38-haut-sonde dil38-joint dil38-illustration 1/4 PDF VERSION CASE STUDY LES CARACTÉRISTIQUES DE LA SONDE DIL38 Technical Specifications ✓ Diameter : 38 mm ✓ Length : 2150 mm ✓ Weight : 6.20 Kg ✓ Max. Temp : 70°C ✓ Max. Pressure : 200 bar Options And Accessories ✓ Gamma ray sensor: ø25 x 50 mm NaI(Tl) crystal ✓ Centralisers non-magnetic ✓ Calibration jig ✓ Transport case Sensors Parameters ✓ Effective spacing : 510 mm (ILM) ; 810 mm (ILD) ✓ Operating frequency : 39.0625 KHz ✓ Range : 0.2 to 5.500 mS/m (about 0.22 Ohm.mFS ✓ Resolution (background noise) : 0.25 mS (mmho) > resolves 4000 Ohm.m ✓ Accuracy / drift : 5 mS/m (5 mmho) over all temp. range All downhole probes

  • DRILLING DATA PROCESSING, DRILLING PERFORMANCE | LIM SAS

    Our drilling data processing solutions enable you to automatically import your borehole logs (Drill@Lim), pre-process and process your borehole logs using Geo-Log 4. Manage and maintain your fleet of machines with Drill@Lim. Data transmitted by Wifi, 4G, USB, applications available on the web. Improve your drilling performance DATA PROCESSING CLOUD-BASED SOLUTIONS GEO-LOG 4 Continuer DRILL@LIM & LIM@MAIL Continuer LIMsoft Continuer Back

  • NEWSLETTER | LIM GROUP

    Newsletter LIM LOGGING, Newsletter LIM SAS, Newsletter LIM, Newsletter LIM instrumentation NEWSLETTERS Newsletter - Borehole logging No.1 Newsletter - Borehole logging No.1 Newsletter - Borehole logging No.2 Newsletter - Borehole logging No.1 Newsletter - Borehole logging No.1 Newsletter - Borehole logging No.1 Newsletter - Instrumentation No.2 Newsletter - Instrumentation No.1 Newsletter - Instrumentation No.2 Newsletter - Borehole logging No.1 Newsletter - Borehole logging No.2

  • SERVICES | LIM LOGGING

    Prestations de diagraphies, Mesures Géophysique de forage GEOPHYSICAL LOGGING SERVICES GEOPHYSICAL BOREHOLE LOGGING In-situ physical formation parameters Fluid properties and aquifer localisation Acoustic/optical borehole imaging Borehole geometry, trajectory, quality control MOBILISATION Teams and equipment available in France/Belgium/Luxembourg DATA PROCESSING Client-orientated data processing and presentation High-level technical approach Internal developments for specific requirements QUALITY AND HSE Focus on health, safety and the environment Equipment maintenance and calibration according to internal QC procedures Services according to industry « best practices » Policy of continual improvement ➭ CONTACT US

  • InclinoLIM-2D | LIM SAS

    InclinoLIM, InclinoLIM-2D, 2D angles indication of the drill mast. InclinoLIM 2D The InclinoLIM 2D , a LIM fifth generation product is an angle indicato r which displays in real time the 2D pitch tilt of drill mast (X, Y ±70° relative to the vertical). The InclinoLIM 2D , can be installed on any type of drill rig in cab or outside (IP 68). Contact us to get a quote or request more information. PDF VERSION InclinoLIM 2D SPECIFICATIONS Realtime Display Real time indication of the drill mast inclination in the two X and Y directions at 1/10th of a degree. CAN BUS Technology C.A.N. BUS (Controller Area Network) technology. Back-Lit LCD Screen Back-lit LCD screen 8 mm heigth with 2 lines of 16 characters. ALARM Version ALARM version to measure the pitch and roll of the drill rig chassis. A visual and sonor signal notifies the operator when the pre-entered limit angles are reached. InclinoLIM 2D: PHOTO GALLERY To play, press and hold the enter key. To stop, release the enter key. VisuaLIM

  • FISHING TOOL | LIM LOGGING

    Tool for retrieving probes stuck in a borehole. Fishing tool Fishing Tool – Probe Recovery Accessory for Boreholes The fishing tool is designed for borehole. Is robust and easy to use, the fishing tool is a recovery device made of steel. It measures 1 meter in length and 70 mm in diameter, making it compatible with NQ diameter boreholes or larger. Technical specifications: Weight: approximately 10 kg Connector: supplied with a perforated female BQ connector, allowing water injection to dislodge soil or debris that may hinder recovery Compatibility: designed for LIM probe heads with 38 mm and 42 mm diameters Installation: quick and easy, can be installed in less than 10 minutes on site Material: steel, for increased strength and durability This fishing tool is particularly useful for logging operations requiring fast and reliable field intervention. It will be available in the Logging Accessories section, alongside the probe pusher and pulleys. The installation manual is available in the Support section of the website.

  • DTN38 probe | LIM LOGGING

    DTN38, Dual Neutron thermal probe, neutron neutron, dual neutron. DTN38: Dual Thermal Neutron The standard DTN38 probe provides long-(LSN) and short-spaced(SSN) 4π thermal neutron measurements. Since the probe reacts strongly to hydrogen content, the principal application of this method is for formation water content (porosity) measurement. As an option (highly recommended), the probe can be supplied with a natural g amma detector to permit the influence of clay content on the results to be evaluated. Useful when the probe is deployed for through-tubing oil/water/air contact measurements, a casing collar locator (CCL) detector is also available as a factory-fitted option for this probe. Contact us to get a quote or request more information. PDF VERSION DTN38 SPECIFICATIONS Technical Specifications ✓ Diameter : 38 mm ✓ Length : 2330 mm ✓ Weight : 12 Kg ✓ Max. Temp : 70°C ✓ Max. Pressure : 200 bar Sensors Parameters ✓ Thermal neutron detectors : 25x200mm He³tube(4 bar) ✓ Source – detector spacings : 24 cm (SSN), 48 cm (LSN) ✓ Source type : Am/Be (mean energy 4MeV) ✓ Recommended source activity : 37 GBq (1 Ci) Options And Accessories ✓ Source holder ✓ Source transport container ✓ Natural gamma detector : ø25 x 50mm NaI(Tl) crystal ✓ CCL detector Borehole Conditions ✓ Fluid-filled borehole recommended ✓ Open or cased borehole All downhole probes

  • FOR DRILL & BLAST | LIM SAS

    GNSS (GPS) guidance of the drill rig via RTK GPS, recording of drilling-mining parameters, drilling deviation. Drill fleet management via Drill@LIM. DRILL-BLAST NaviLIM High-precision GNSS (GPS) guidance of the drill. PocketLIM 6G Blasting version. Drill@LIM Drilling machine fleet management. DeviaLIM Drilling deviation. Data processing and transmission : Cloud@LIM GEO-LOG 4 web application for processing drilling and mining data. More LIM@mail is a service that automatically synchronises, downloads and pre-processes your drilling data. More ➭ CONTACT US

  • ScanLIM | LIM SAS

    ScanLIM, Core scanner, Core scanner LIBS. ScanLIM-2 The ScanLIM-2 allows the user to create a virtual "corestore" of high quality, true colour and correctly scaled digital images. With a few mouse clicks, it is possible to retrieve and display selected zones or reconstruct an entire borehole. Borehole information is included in the data files in order to ensure systematic archiving. The system is transported in kit form and can be assembled and operational on site within 20 minutes. The core scaning itself is a oneman operation. Contact us to get a quote or request more information. PDF VERSION Back ScanLIM SPECIFICATIONS ✓ Dimensions: 230 cm x 120 cm x 60 cm / 90.5" x 47.2" x 23.6"; ✓ Operating temperature : +5°C à +45°C / 41°F to 113°C; ✓ Storage temperature : -25°C à +60°C / -13°F to 140°F; ✓ Humidity : 20% to 80% non-condensing; ✓ Camera : Matrix caméra, 4096 pixels/line, 100 millions of pixels for a one meter (3.3 ft) image; ✓ Image format : jpeg; ✓ HMI: Dedicated laptop provided by LIM with specific OS; ✓ Max length acquisition : 120 cm / 47.2"; ✓ Max width acquisition : 15 cm / 5.9"; ✓ Lighting : Natural/UV short 280nm, UV long 385nm; ✓ Maximum acquisition speed: 2 m/min / 6.5ft/min; ✓ Power Supply : 110 to 220 VAC; ✓ Positioning aid: laser & optical; ✓ Auto image calibration. Technical Specifications ScanLIM: PHOTO GALLERY To play, press and hold the enter key. To stop, release the enter key.

  • PDS system | LIM LOGGING

    PDS, Probe Deployment System, Borehole logging horizontal boreholes, Borehole logging upward boreholes. PDS: Probe Deployment System The PDS allows OPTV and BHTV imaging probes and certain other types of probe to be deployed in steeply inclined, horizontal or up-holes, where assistance from a drilling machine is required. It has been successfully used in boreholes exceeding 400 m in length. The main housing containing the probe is manufactured from aluminium and the standard kit includes 2 x 2 m aluminium rods to allow imaging probes to operate in non magnetically disturbed conditions. A variety of nose cones, adapted to different types of probe, and housing centraliser blades for boreholes of up to 150 mm diameter can be supplied. Behind the housing the logging cable runs along the outside of the drill rods (AQ or BQ recommended). The drill rod adapter incorporates a centraliser to support the weight of the drill string. A precise depth measurement is obtained using the lateral movement of the drilling machine’s drive head. Contact us to get a quote or request more information. PDF VERSION PROBE DEPLOYMENT SYSTEM SPECIFICATIONS Technical Specification ✓ Diameter : 75 mm (excluding centralisers) ✓ Weight: varies according to configuration. ✓ Length : 6850 mm (typical configuration for BHTV42 including 2 x 2 m non-magnetic rods) Sensors Parameters ✓ Depth measurement: auto-return steel cable system, 50 cm wheel with optical encoder 5v/750 ppr Borehole Conditions ✓ Borehole diameter: HQ (96 mm) and above. All downhole probes

bottom of page